 | REO   PURE FILTER SERVICE LIFE AND CHANGE INTERVALS: 
 
 
                                                    
                             
          
Sediment  Pre-Filter   - Change every 6-12 months     (more often in areas
with very  high sediment   in the water).    
                                                        
    
          
Carbon  Post-Filter   These filters should be changed every 1-2 years. 
This  is necessary  to help insure water quality.         
                                                        
          
R.O.  Membrane
  - The R.O. membrane would be changed when     rejection   rate falls to
75%.  The rejection rate should be tested every year.   The membrane
can last  up to 12 years     depending on the water quality, hardness of
the water coming into the     system and the frequency of filter changes.
The only way to know when     it is time to change the membrane is to know
when the rejection rate of TDS falls     below 75%.  To do this
  you will need a              
TDS Meter  (total dissolved solids tester)
This allows you to     compare the amount  of TDS in the incoming water vs.
the purified     water. TDS testers are a basic tool in proper maintenance
on any     reverse osmosis  system.   |